Look up, look down — measured the way a neurologist checks.
This page replicates the eye-movement part of a PSP (progressive supranuclear palsy) examination using your webcam: fixation, saccades, smooth pursuit, and — with a helper — the head-movement reflex test that shows whether a gaze problem is supranuclear.
Important: This is a screening and documentation aid only. It does not diagnose PSP or any other condition. Parkinson’s disease, normal ageing, medication, fatigue, and other neurological conditions can all produce abnormal results, and a normal result does not rule out PSP. Any abnormal result should be discussed with a neurologist.
🔒 Private by design — nothing leaves this device. All eye tracking runs in your browser on this device. No video, images, or measurements are uploaded or saved on a server. The session video is recorded locally in your browser only so you can download it at the end and share it with a clinician if you choose.
What it measures
Vertical vs horizontal range — the core PSP comparison (O1)
How long vertical movements take and whether they arrive in a staircase of small steps — a proxy for slow saccades (O2). At webcam frame rates this is reported as duration, not true peak velocity in degrees/second.
Square-wave jerks during fixation (O3)
Smooth pursuit breakup and catch-up saccades
Reflex range when a helper moves your head — voluntary vs reflex is the supranuclear comparison
What you need
A laptop on a desk is best — big screen, fixed camera. A tablet/phone works only on a stand at eye level, never handheld.
Sit 50–70 cm from the screen, face well lit, no bright window behind you.
Glasses can cause glare — if tracking is poor, try without them if you can still see the dot.
Optional for the final phase: a second person to move your head gently.
Sound on if you can: the instructions are also spoken aloud, so you can keep your eyes on the dot instead of reading the screen. In the “look on command” trials the direction itself is spoken, the way a neurologist gives it. You can switch spoken instructions off with the toggle below — the test then runs on on-screen text alone.
Time: about 3–4 minutes, plus ~1 minute for the optional helper phase.
Results are reported as a pattern — no abnormality detected / non-specific abnormality / PSP-type supranuclear pattern / vertical limitation that does not look supranuclear — with the underlying numbers, so a neurologist can judge for themselves.
Camera didn’t start
0 · Setup & quality check
Spoken instructions aren’t available here — the test will use on-screen text.
Centre your face in the frame, at arm’s length (50–70 cm). Keep your head still from here on — move only your eyes unless the test says otherwise. If someone is helping, they can gently hold the sides of your head still during the solo phases.
Your camera preview — this video stays on this device.
Camera quality gate
Resolution—measuring…
Real frame rate—measuring…
Face tracking · last 10 s—looking for face…
Position: waiting… Move until it says “Good — centred and a good size.”
We need at least 720p and ~25 fps with stable tracking. Face tracking is judged on the last 10 seconds only — stepping away and coming back won’t block you once you’ve been tracking well for a few seconds again. Below that, range and timing numbers become unreliable and the page will tell you rather than quietly produce a bad result.
Measuring… keep your face centred and look at the camera.
Calibration
Follow the dot with your eyes only — keep your head still
+
UP
Keep your head still. Blink normally. If you lose the dot, just look back to the centre.
4 · Helper phase — head-movement (reflex) test
This is the manoeuvre that makes the test specific: you fixate the centre dot and relax while a second person passively tilts your head. If the reflex range is much larger than your voluntary range, that is the supranuclear pattern.
Stop — safety check first
Skip this phase entirely if any of these apply to the person being tested:
!Neck pain, injury, or recent cervical surgery
!Cervical arthritis, known neck instability, or osteoporosis of the neck
!Dizziness, vertigo, or nausea when the head is moved
!Any doubt at all — when in doubt, skip. The solo results are still useful without this phase.
Instructions for the helper
Stand behind the seated person (so your arms don’t block the camera), hands low on either side of their head.
They keep looking at the centre dot and relax — they should not try to move their eyes or help with the movement.
On the on-screen prompts, tilt the head slowly up, then down — about 20–30°, never forced. Follow the pacing text.
Stop immediately on any pain, dizziness, or nausea.
Optional polish: helper cues can be heard through one earbud paired to this device, so the person being tested isn’t anticipating — but it isn’t crucial, because the reflex is involuntary and they will feel the movement anyway.
Your results
Screening / documentation only — not a diagnosis. Take this summary and the video to a neurologist for interpretation.
Saccades — per direction
Range is vs your own calibration maximum. Duration is time to reach the target (a proxy for slowness at webcam frame rates — not peak velocity). Steps >1 means the eye arrived in a staircase of small movements (hypometria).
Direction
Range
Median duration
Steps
Latency
Traces: vertical (teal) and horizontal (amber) eye-in-head position over the saccade phase, from the recorded samples.
Fixation
Smooth pursuit
Voluntary vs reflex vertical range
Why this pattern?
What to do next: If anything here is abnormal — or if you have falls, stiffness, slowness, speech/swallowing change, or trouble looking down to read or use stairs — see a neurologist, ideally a movement-disorder specialist. Some PSP mimics are treatable or urgent, which is another reason an abnormal eye result always needs in-person assessment. A normal result here does not rule out PSP, especially early on.
To print this summary, download the results and open this page in your browser, or print the downloaded summary from your clinician’s system — the layout above is print-clean.
For the clinician — methods & limits
Webcam eye tracking (MediaPipe Face Landmarker / Face Mesh, iris landmarks 468–478, on-device). Eye-in-head position = iris centre relative to eye corners, averaged over both eyes, blink frames excluded, lightly smoothed. Head pitch from face landmarks / pose. Calibration is per-person 5-point. Saccade “duration” is time-to-target at the measured camera frame rate — it is not peak saccadic velocity (which needs 500–1000 Hz). All ratios are within-person, within-session (vertical vs that person’s own horizontal), which is the comparison the MDS PSP ocular criteria (O1–O3) rely on. Quality gate data is included in the JSON download. Instructions are also given as pre-recorded spoken audio where available (the printed text remains on screen as captions). In the “to command” saccade trials, the command is delivered by pre-recorded audio where available and latency is timed from the onset of audio playback; where audio is unavailable or switched off, the command is shown as on-screen text instead and latency is timed from when the word appears — the JSON download records which mode was used (commandMode).
PSP Eye Test — a screening & documentation aid replicating the ocular part of the MDS PSP examination (O1 vertical gaze palsy · O2 slow vertical saccades · O3 fixation / square-wave jerks, plus the oculocephalic reflex check). It does not diagnose any condition.